Tritex II® AC Linear Actuator:

  • T2M/X075
    • Performance Specifications

      T2M/X075 Mechanical Specifications

        Stator1 Stack2 Stack3 Stack
      LeadRPM @ 240 VAC400030002000
      0.1Continuous Forcelbf (N)589 (2,620)990 (4,404)NA
      Peak Forcelbf (N)1,178 (5,240)1,980 (8,808)***NA
      Max Speedin/sec (mm/sec)6.67 (169)5.00 (127)NA
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)5516 (24536)5516 (24536)NA
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3310 (14724)3310 (14724)NA
      0.2Continuous Forcelbf (N)334 (1,486)561 (2,496)748 (3,327)
      Peak Forcelbf (N)668 (2,971)1,122 (4,991)1,495 (6,650)
      Max Speedin/sec (mm/sec)13.33 (339)10.00 (254)6.67 (169)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)5800 (25798)5800 (25798)5800 (25798)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3570 (15880)3570 (15880)3570 (15880)
      0.5Continuous Forcelbf (N)141 (627)238 (1,059)317 (1,410)
      Peak Forcelbf (N)283 (1,259)475 (2,113)633 (2,816)
      Max Speedin/sec (mm/sec)33.33 (847)25.00 (635)16.67 (423)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)4900 (21795)4900 (21795)4900 (21795)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3016 (13416)3016 (13416)3016 (13416)
      Drive Current @
      Continuous Force
      Amps3.13.83.6
      Available Stroke
      Lengths
      in (mm)3 (76), 6 (152), 10 (254),
      12 (305), 14 (356), 18 (457)
      Inertia
      (zero stroke)
      lb-in-s^2/ Kg-m^20.002655 (0.000003000)0.002829 (0.000003196)0.003003 (0.0000033963)
      Inertia Adder
      (per inch of stroke)
      lb-in-s^2/in/ Kg-m^2/in0.0001424 (0.0000001609)0.0001424 (0.0000001609)0.0001424 (0.0000001609)
      Inertia Adder
      (per inch of stroke)
      lb (kg)10.8 (4.9) for 3 inch stroke, 1 stack.
      Add 1.1 (0.5) per inch of stroke.
      Add 1.1 (0.5) per motor stack.
      Add .8 (0.4) for brake.
      Operating
      Temperature
      Range*
      -20C to 65C
      (-40˚C available, consult Exlar)
      Continuous AC
      Input Current**
      Amps4.343.6
      * Ratings based on 40˚C conditions.
      ** Continuous input current rating is defined by UL and CSA
      *** T2X peak force for 0.1 inch lead is 1980 lbf (8808 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).

       

    • Data Curves

      T2M075 - 1 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 10″ x 10″ x 3/8″ at 40°C ambient.

       

       

       


      T2M075 - 2 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 10″ x 10″ x 3/8″ at 40°C ambient.
      **T2X peak force for 0.1 inch lead is 1980 lbf (8808 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).

       

       

       


      T2M075 - 3 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 10″ x 10″ x 3/8″ at 40°C ambient.

       

    • Estimated Life Time Curves

      T2M075-090 Travel Life

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      T2M Order

       

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AAA = Actuator Type

      T2M = Tritex II Linear Actuator, standard mechanical capacity
      T2X = Tritex II Linear Actuator, high mechanical capacity

       

      BBB = Actuator Frame Size

      075 = 75 mm
      090 = 90 mm
      115 = 115 mm

       

      CC = Stroke Length (nominal)

      03 = 3 inch (76 mm) (T2M/X075, 090)
      04=  4 inch (102 mm) (T2M/X115)
      06 = 6 inch (150 mm)
      10 = 10 inch (254 mm)
      12 = 12 inch (305 mm)
      18 = 18 inch (457 mm)

       

      DD = Lead (linear travel per screw revolution)

      01 = 0.1 inch (2.54 mm)
      02 = 0.2 inch (5.08 mm)
      05 = 0.5 inch (12.7 mm)
      08 = 0.75 inch (19.05 mm) (T2M/X115 only)*

       

      *0.75 lead not available above 12 inch stroke.

       

      E = Connections

      G = Standard straight threaded port with internal terminals, M20x1.5
      N = NPT threaded port via adapter with Internal terminals, 1/2″ NPT
      I = Interconnect style – Exlar std, M16/M23 style connector.

       

      F = Mounting

      C = Rear Clevis
      D = Double Side Mount
      E = Extended Tie Rod
      F = Front Flange
      G = Metric Rear Clevis
      K = Metric Double Side Mount
      M = Metric Extended Tie Rod
      Q = Metric Side Trunnion
      R = Rear Flange
      T = Side Trunnion

       

      G = Rod End

      A = Male Metric Thread *
      B = Female Metric Thread*
      F = Female US Standard Thread *
      M = Male US Standard Thread *

      *Chrome-plated carbon steel. Threads not chrome-plated.

      HH = Feedback Type

      HD = Analog Hall Device
      IE = Incremental Encoder, 8192 count resolution
      AF = Absolute Feedback

       

      III-II = Motor Stator, All 8 Pole

      T2M/X075
      138-40 = 1 stack, 230 VAC, 4000 rpm
      238-30 = 2 stack, 230 VAC, 3000 rpm
      338-20 = 3 stack, 230 VAC, 2000 rpm

       

      T2M/X090
      138-40 = 1 stack, 230 VAC, 4000 rpm
      238-40 = 2 stack, 230 VAC, 4000 rpm
      238-30 = 2 stack, 230 VAC, 3000 rpm*

       

      T2M/X115
      138-30 = 1 stack, 230 VAC, 3000 rpm
      238-20 = 2 stack, 230 VAC, 2000 rpm
      238-15 = 2 stack, 230 VAC, 1500 rpm (N/A with 0.1″ lead)

       

      * N/A with 0.1″ lead.

       

       

      JJJ = Voltage

      230 = 115-230 VAC, single phase

       

      KKK = Option  Board

      SIO = Standard I/O Interconnect
      IA4 = SIO plus isolated 4-20mA Analog I/O
      EIP = SIO plus Ethernet/IP with M12 connector
      EIN = SIO plus Ethernet/IP without M12 connector*
      PIO = SIO plus Profinet IO with M12 connector
      PIN = SIO plus Profinet IO without M12 connector*
      TCP = SIO plus Modbus TCP/IP with M12 connector
      TCN – SIO plus Modbus TCP/IP without M12 connector*
      COP = CANopen with M12 connector
      CON = CANopen non-connectorized*

       

      * Requires customer supplied Ethernet cable through I/O port for Class I Division 2 compliance only.

       

       

      MM = Mechanical Options

      AR = External Anti-rotate
      L1/2/3 = External Limit Switches (2)
      RB = Rear Brake
      SR = Splined Main Rod (1)

       

      1. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
      2. Limit switch option requires AR option

       

      For extended temperature operation consult factory for model number.

      Consult Exlar when ordering splined stainless steel main rod.

       

  • T2M/X090
    • Performance Specifications

      T2M/X090 Mechanical Specifications

        Stator1 Stack2 Stack2 Stack
      LeadRPM @ 240 VAC400040003000
      0.1Continuous Forcelbf (N)1,130 (5062)1,488 (6619)NA
      Peak Forcelbf (N)2,260 (10053)2,700 (12010)***NA
      Max Speedin/sec (mm/sec)6.67 (169)6.67 (169)NA
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)5516 (24536)5516 (24536)NA
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3310 (14724)3310 (14724)NA
      0.2Continuous Forcelbf (N)640 (2847)843 (3750)1,113 (4951)
      Peak Forcelbf (N)1,281 (5698)1,687 (7504)2,225 (9897)
      Max Speedin/sec (mm/sec)13.33 (338)13.33 (338)10.00 (254)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)5800 (25798)5800 (25798)5800 (25798)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3570 (15880)3570 (15880)3570 (15880)
      0.5Continuous Forcelbf (N)271 (1205)357 (1588)471 (2095)
      Peak Forcelbf (N)542 (2410)714 (3176)942 (4190)
      Max Speedin/sec (mm/sec)33.33 (846)33.33 (846)25.00 (635)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)4900 (21795)4900 (21795)4900 (21795)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3016 (13416)3016 (13416)3016 (13416)
      Drive Current @
      Continuous Force
      Amps5.77.57.5
      Available Stroke Lengthsin (mm)3 (76), 6 (152),
      10 (254), 12 (305),
      18 (457)
      Inertia (zero stroke)lb-in-s^2/ Kg-m^20.002655 (0.000003000)0.002829 (0.000003196)0.003003 (0.0000033963)
      Inertia Adder (per inch of stroke)lb-in-s^2/in/ Kg-m^2/in0.0001424 (0.0000001609)0.0001424 (0.0000001609)0.0001424 (0.0000001609)
      Approximate Weight lb (kg)14 (6.35) for 3 inch stroke, 1 stack.
      Add 1 (0.5) per inch of stroke.
      Add 3 (1.4) per motor stack.
      Add 3 (1.4) for brake.
      Operating Temperature Range*-20 to 65˚ C (-40˚C available, consult Exlar)
      Continuous AC Input Current**Amps6.36.36.3
      * Ratings based on 25˚C conditions.
      ** Continuous input current rating is defined by UL and CSA
      *** T2X peak force for 0.1 inch lead is 2700 lbf (12,010 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).

    • Data Curves

      T2M090 - 1 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 10″ x 10″ x 3/8″ at 25°C ambient.

       


      T2M090 - 2 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 10″ x 10″ x 3/8″ at 25°C ambient.
      **T2X peak force for 0.1 inch lead is 2700 lbf (12010 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).

       

       


      T2M090 - 2 Stack 3000 rpm

       

       

      *Test data derived using NEMA recommended aluminum heatsink 10″ x 10″ x 3/8″ at 25°C ambient.

       

    • Estimated Life Time Curves

      T2M075-090 Travel Life

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      T2M Order

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AAA = Actuator Type

      T2M = Tritex II Linear Actuator, standard mechanical capacity
      T2X = Tritex II Linear Actuator, high mechanical capacity

       

      BBB = Actuator Frame Size

      075 = 75 mm
      090 = 90 mm
      115 = 115 mm

       

      CC = Stroke Length (nominal)

      03 = 3 inch (76 mm) (T2M/X075, 090)
      04=  4 inch (102 mm) (T2M/X115)
      06 = 6 inch (150 mm)
      10 = 10 inch (254 mm)
      12 = 12 inch (305 mm)
      18 = 18 inch (457 mm)

       

      DD = Lead (linear travel per screw revolution)

      01 = 0.1 inch (2.54 mm)
      02 = 0.2 inch (5.08 mm)
      05 = 0.5 inch (12.7 mm)
      08 = 0.75 inch (19.05 mm) (T2M/X115 only)*

       

      *0.75 lead not available above 12 inch stroke.

       

      E = Connections

      G = Standard straight threaded port with internal terminals, M20x1.5
      N = NPT threaded port via adapter with Internal terminals, 1/2″ NPT
      I = Interconnect style – Exlar std, M16/M23 style connector.

       

      F = Mounting

      C = Rear Clevis
      D = Double Side Mount
      E = Extended Tie Rod
      F = Front Flange
      G = Metric Rear Clevis
      K = Metric Double Side Mount
      M = Metric Extended Tie Rod
      Q = Metric Side Trunnion
      R = Rear Flange
      T = Side Trunnion

       

      G = Rod End

      A = Male Metric Thread *
      B = Female Metric Thread*
      F = Female US Standard Thread *
      M = Male US Standard Thread *

      *Chrome-plated carbon steel. Threads not chrome-plated.

      HH = Feedback Type

      HD = Analog Hall Device
      IE = Incremental Encoder, 8192 count resolution
      AF = Absolute Feedback

       

      III-II = Motor Stator, All 8 Pole

      T2M/X075
      138-40 = 1 stack, 230 VAC, 4000 rpm
      238-30 = 2 stack, 230 VAC, 3000 rpm
      338-20 = 3 stack, 230 VAC, 2000 rpm

       

      T2M/X090
      138-40 = 1 stack, 230 VAC, 4000 rpm
      238-40 = 2 stack, 230 VAC, 4000 rpm
      238-30 = 2 stack, 230 VAC, 3000 rpm*

       

      T2M/X115
      138-30 = 1 stack, 230 VAC, 3000 rpm
      238-20 = 2 stack, 230 VAC, 2000 rpm
      238-15 = 2 stack, 230 VAC, 1500 rpm (N/A with 0.1″ lead)

       

      * N/A with 0.1″ lead.

       

       

      JJJ = Voltage

      230 = 115-230 VAC, single phase

       

      KKK = Option  Board

      SIO = Standard I/O Interconnect
      IA4 = SIO plus isolated 4-20mA Analog I/O
      EIP = SIO plus Ethernet/IP with M12 connector
      EIN = SIO plus Ethernet/IP without M12 connector*
      PIO = SIO plus Profinet IO with M12 connector
      PIN = SIO plus Profinet IO without M12 connector*
      TCP = SIO plus Modbus TCP/IP with M12 connector
      TCN – SIO plus Modbus TCP/IP without M12 connector*
      COP = CANopen with M12 connector
      CON = CANopen non-connectorized*

       

      * Requires customer supplied Ethernet cable through I/O port for Class I Division 2 compliance only.

       

       

      MM = Mechanical Options

      AR = External Anti-rotate
      L1/2/3 = External Limit Switches (2)
      RB = Rear Brake
      SR = Splined Main Rod (1)

       

      1. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
      2. Limit switch option requires AR option

       

      For extended temperature operation consult factory for model number.

      Consult Exlar when ordering splined stainless steel main rod.

       

  • T2M/X115
    • Performance Specifications

      T2M/X115 Mechanical Specifications

        Stator1 Stack2 Stack2 Stack
      LeadRPM @ 240 VAC300020001500
      0.1Continuous Forcelbf (N)2,060 (9,163)3,224 (14,341)NA
      Peak Forcelbf (N)4,120 (18,327)5,400 (24,020)*** NA
      Max Speedin/sec (mm/sec)5.00 (127)3.33 (84)NA
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)7900 (35141)7900 (35141)NA
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)4736 (21067)4736 (21067)NA
      0.2Continuous Forcelbf (N)1,177 (5,235)1,843 (8,198)2,380 (10,586)
      Peak Forcelbf (N)2,354 (10,471)3,685 (16,392)4,760 (21,174)
      Max Speedin/sec (mm/sec)10.00 (254)6.67 (169)5.00 (127)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)8300 (36920)8300 (36920)8300 (36920)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)4890 (21751)4890 (21751)4890 (21751)
      0.5Continuous Forcelbf (N)530 (2,358)829 (3,688)1,071 (4,764)
      Peak Forcelbf (N)1,059 (4711)1,658 (7,375)2,142 (9,528)
      Max Speedin/sec (mm/sec)25.00 (635)16.67 (423)12.50 (317)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)7030 (31271)7030 (31271)7030 (31271)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)4218 (18763)4218 (18763)4218 (18763)
      0.75Continuous Forcelbf (N)353 (1,570)553 (2,460)714 (3,176)
      Peak Forcelbf (N)706 (3,140)1,106 (4,920)1,428 (6,352)
      Max Speedin/sec (mm/sec)37.5 (953)25 (635)17.75 (450)
      T2X - C_a
      (Dynamic Load Rating)
      lbf (N)6335 (28179)6335 (28179)6335 (28179)
      T2M - C_a
      (Dynamic Load Rating)
      lbf (N)3328 (14804)3328 (14804)3328 (14804)
      Drive Current @
      Continuous Force
      Amps8.58.58.5
      Available Stroke Lengths in (mm)4 (102), 6 (152),
      10 (254), 12 (305), 18 (457)
      Inertia (zero stroke)lb-in-s2/ Kg-m20.01132 (0.000012790)0.01232 (0.00001392)0.01332 (0.00001505)
      Inertia Adder
      (per inch of stroke)
      lb-in-s2/in/ Kg-m2/in0.0005640 (0.0000006372)0.0005640 (0.0000006372)0.0005640 (0.0000006372)
      Approximate Weight lb (kg)34 (15.5) for 6 inch stroke, 1 stack.
      Add 2 (1) per inch of stroke.
      Add 8 (4) per motor stack.
      Add 4 (2) for brake.
      Operating Temperature Range*-20 to 65˚ C (-40˚C available, consult Exlar)
      Continuous AC Input Current**Amps8.38.38.3
      * Ratings based on 25˚C conditions.
      ** Continuous input current rating is defined by UL and CSA
      *** T2X peak force for 0.1 inch lead is 5400 lbf (24,020 N). T2M peak force for 0.1 inch lead limited to 3966 lbf (17,642 N).
    • Data Curves

      T2M115 - 1 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 12″ x 12″ x 1/2″ at 25°C ambient.

       

       


      T2M115 - 2 Stack

       

      *Test data derived using NEMA recommended aluminum heatsink 12″ x 12″ x 1/2″ at 25°C ambient.
      **T2X peak force for 0.1 inch lead is 5400 lbf (24020 N). T2M peak force for 0.1 inch lead limited to 3966 lbf (17,642 N).

       

       


      T2M115- 2 Stack 1500 rpm

       

      *Test data derived using NEMA recommended aluminum heatsink 12″ x 12″ x 1/2″ at 25°C ambient.

       

    • Estimated Life Time Curves

      T2M115 Travel Life

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      T2M Order

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AAA = Actuator Type

      T2M = Tritex II Linear Actuator, standard mechanical capacity
      T2X = Tritex II Linear Actuator, high mechanical capacity

       

      BBB = Actuator Frame Size

      075 = 75 mm
      090 = 90 mm
      115 = 115 mm

       

      CC = Stroke Length (nominal)

      03 = 3 inch (76 mm) (T2M/X075, 090)
      04=  4 inch (102 mm) (T2M/X115)
      06 = 6 inch (150 mm)
      10 = 10 inch (254 mm)
      12 = 12 inch (305 mm)
      18 = 18 inch (457 mm)

       

      DD = Lead (linear travel per screw revolution)

      01 = 0.1 inch (2.54 mm)
      02 = 0.2 inch (5.08 mm)
      05 = 0.5 inch (12.7 mm)
      08 = 0.75 inch (19.05 mm) (T2M/X115 only)*

       

      *0.75 lead not available above 12 inch stroke.

       

      E = Connections

      G = Standard straight threaded port with internal terminals, M20x1.5
      N = NPT threaded port via adapter with Internal terminals, 1/2″ NPT
      I = Interconnect style – Exlar std, M16/M23 style connector.

       

      F = Mounting

      C = Rear Clevis
      D = Double Side Mount
      E = Extended Tie Rod
      F = Front Flange
      G = Metric Rear Clevis
      K = Metric Double Side Mount
      M = Metric Extended Tie Rod
      Q = Metric Side Trunnion
      R = Rear Flange
      T = Side Trunnion

       

      G = Rod End

      A = Male Metric Thread *
      B = Female Metric Thread*
      F = Female US Standard Thread *
      M = Male US Standard Thread *

      *Chrome-plated carbon steel. Threads not chrome-plated.

      HH = Feedback Type

      HD = Analog Hall Device
      IE = Incremental Encoder, 8192 count resolution
      AF = Absolute Feedback

       

      III-II = Motor Stator, All 8 Pole

      T2M/X075
      138-40 = 1 stack, 230 VAC, 4000 rpm
      238-30 = 2 stack, 230 VAC, 3000 rpm
      338-20 = 3 stack, 230 VAC, 2000 rpm

       

      T2M/X090
      138-40 = 1 stack, 230 VAC, 4000 rpm
      238-40 = 2 stack, 230 VAC, 4000 rpm
      238-30 = 2 stack, 230 VAC, 3000 rpm*

       

      T2M/X115
      138-30 = 1 stack, 230 VAC, 3000 rpm
      238-20 = 2 stack, 230 VAC, 2000 rpm
      238-15 = 2 stack, 230 VAC, 1500 rpm (N/A with 0.1″ lead)

       

      * N/A with 0.1″ lead.

       

       

      JJJ = Voltage

      230 = 115-230 VAC, single phase

       

      KKK = Option  Board

      SIO = Standard I/O Interconnect
      IA4 = SIO plus isolated 4-20mA Analog I/O
      EIP = SIO plus Ethernet/IP with M12 connector
      EIN = SIO plus Ethernet/IP without M12 connector*
      PIO = SIO plus Profinet IO with M12 connector
      PIN = SIO plus Profinet IO without M12 connector*
      TCP = SIO plus Modbus TCP/IP with M12 connector
      TCN – SIO plus Modbus TCP/IP without M12 connector*
      COP = CANopen with M12 connector
      CON = CANopen non-connectorized*

       

      * Requires customer supplied Ethernet cable through I/O port for Class I Division 2 compliance only.

       

       

      MM = Mechanical Options

      AR = External Anti-rotate
      L1/2/3 = External Limit Switches (2)
      RB = Rear Brake
      SR = Splined Main Rod (1)

       

      1. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
      2. Limit switch option requires AR option

       

      For extended temperature operation consult factory for model number.

      Consult Exlar when ordering splined stainless steel main rod.