FT Series:

  • FT35
    • Performance Specifications

      FT35 Mechanical Specifications

        High
      Capacity
        Standard
      Capacity
        
      5102051020
      Screw Leadin0.1970.3940.7870.1970.3940.787
      mm5102051020
      Maximum Force^1lbf500050005000500050005000
      kN22.222.222.222.222.222.2
      Estimated L_10 Life at Maximum Forcein x 10^615.424.656.78.8814.1532.05
      km3926261440225.6359.4814.2
      C_a (Dynamic Load Rating)lbf214001985020800178001650017200
      kN95.288.392.579.273.476.5
      Maximum Input Torquelbf-in196392783196392783
      Nm22.144.388.522.144.388.5
      Max Rated RPM @ Input ShaftRPM450045004500450045004500
      Maximum Linear Speed @
      RPM Maximum Rated
      in/sec14.729.559.314.729.559.3
      mm/sec37375015003737501500
      *FT35 actuators with high capacity screw option are 20 mm longer.
      1- Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

       

      FT35 Inertias

       5 mm Lead10 mm Lead20 mm Lead 
      NMT Unit - J (0)0.00040870.00041210.0004259kg-m² (at input shaft) kg-m²/inch of stroke
      NMT Unit - J (Stroke)0.00001590.00001620.0000171kg-m² (at input shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (0)0.00051270.00051610.0005299kg-m² (at motor shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (Stroke)0.00001590.00001620.0000171kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (0)0.00110420.00118550.001448kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (Stroke)0.00001590.00001620.0000171kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (0)0.00140290.00140380.0015345kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (Stroke)0.00000400.00000400.0000043kg-m² (at motor shaft) kg-m²/inch of stroke
      Standard Inline Coupling Inertia0.000104 kg-m²
      (0.000920 lbf-in s²)
      *Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

       

      FT35 Weights

      Base Actuator Weightlbkg
      6 Inch Stroke Length3014
      12 Inch Stroke Length3516
      18 Inch Stroke Length4018
      24 Inch Stroke Length4521
      36 Inch Stroke Length5525
      48 Inch Stroke Length6530
      Adder for Inline (excluding motor)83.6
      Adder for Parallel Drive (excluding motor)167.3
      Adder for Front Flange5.42.5
      Adder for Rear Flange7.43.4
      Adder for Rear Clevis31.4
      Adder for Rear EyeNANA
      Adder for Front/Rear Angle MountsNANA
      Adder for Two Trunnions19.58.9
      Adder for Two Foot Mounts3.31.5
    • Data Curves

      F35 Critical Speed

       


      FT35 Max Force

       

    • Estimated Life Time Curves

      FT35 Series Life Curves


      FT35A Series Life Curves (3)

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      FT Order

       

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AA = Frame Size

      35 = 3.5 inch (90 mm)
      45 = 4.8 inch (122 mm)
      60 = 6.4 inch (162 mm)
      80 = 8.5 inch (216 mm)

       

      BB = Stroke Length

      06 = 6 inch (152 mm) FT35
      12 = 12 inch (305 mm) FT35, 45, 60, 80
      18 =18 inch (457 mm) FT35, 45
      24 = 24 inch (610 mm) FT35, 45, 60, 80
      36 = 36 inch (914 mm) FT35, 45, 60, 80
      48 = 48 inch (1219 mm) FT35, 45, 60, 80

       

      CC= Screw Lead

      05 = 0.2 inch, FT35, 45
      06 = 0.23 inch, FT60, 80
      10 = 0.39 inch, FT35, 45
      12 = 0.47 inch, FT60, 80
      20 = 0.79 inch, FT35
      30 = 1.18 inch, FT60, 80

       

      D = Mounting Style

      N = None
      F = Front flange, English
      Z = Front flange, Metric, FT45
      R = Rear flange, English 1,2
      C = Rear clevis, English 1,2
      G = Rear clevis, Metric 1,2
      Y = Rear eye, English 1, FT45
      W = Rear eye, Metric 1, FT45
      L = Side lugs
      S = Side mount, English, FT35, 60, 80
      J = Side mount, Metric, FT35, 60, 80
      T = Side trunnion mount, English 2,3, FT35, 60, 80
      Q = Side trunnion mount, Metric 2,3, FT35, 60, 80
      2 = Rear trunnion mount, English, FT45
      P = Rear trunnion mount, Metric, FT45
      E = Extended tie rods, English
      M = Extended tie rods, Metric

       

      Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

       

      1. Not available with inline motor mount, contact your local sales representative.
      2. Application details must be discussed for an FT80
      3. IP65 environmental sealing option not available

       

       

      E= Motor Mounting Configurations

      N = None
      I = Inline direct drive (includes Exlar standard coupling)
      P = Parallel, 1:1 belt reduction
      Q = Parallel, 2:1 belt reduction

       

      Maximum Standard Motor Size

      FT35: 5.6 inch/165 mm
      FT45: 7.1 inch/215 mm
      FT60: 7.9 inch/215 mm
      FT80: 8.5 inch/300 mm
      For oversized motors, contact your local sales representative.

       

      F= Rod End

      M= Male, US std. thread
      A= Male, metric thread
      F= Female, US std. thread
      B= Female, metric thread

       

      GGG = Motor Mount Provisions

      AA# = Alpha numeric motor call out – Contact your local sales representative. Motor not included.

       

      NMT = No motor mount – keyed shaft on base unit only
      N23 = Nema 23 standard dimension
      N34 = Nema 34 standard dimension
      N42 = Nema 42 standard dimension
      N56 = Nema 56 standard demension
      M60 = Exlar 60 mm SLM. Motor not included.
      M90 = Exlar 90 mm SLM. Motor not included.
      M11 = Exlar 115 mm SLM and ER. Motor not included.
      M14 = Exlar 142 mm SLM. Motor not included.
      M18 = Exlar 180 mm SLM. Motor not included.
      G60 = Exlar 60 mm SLG. Motor not included.
      G90 = Exlar 90 mm SLG. Motor not included.
      G11 = Exlar 115 mm SLG and ER. Motor not included.
      AB3, 4, 6, 8 = Allen Bradley Ultra 3, 4, 6 and8 inch motors
      BD3, 4, 6, 8 = Baldor 3, 4, 6 & 8 inch motors
      CM3, 4, 6, 8 = Parker (Custom Servo Motors) Metric 3, 4, 6 & 8 inch motors
      EE3, 4 = Emerson EMC Imperial 3 & 4 inch
      EM3, 4, 6, 8 = Emerson EMC Metric 3, 4, 6 &8 inch
      FA 4, 6, 8 = Fanuc 4, 6 & 8 inch motors
      IN3, 4, 6, 8 = Bosch-Rexroth (Indramat) 3, 4, 6 and 8 inch motors
      KM2, 4, 6, 8 = Kollmorgen B & M 20, 40, 60 and80 Series
      MT3, 4, 6, 8 = Mitsubishi 3, 4, 6 & 8 inch motors
      PS3, 4, 6, 8 = Pacific Scientific PMA/PMB Series
      PC2, 3, 4, 6 = Parker Compumotor Apex 2.7, 3.6, 4.5 and 5.6 inch
      SM2 = Siemens 2 inch motor
      SM3 = Siemens 3 inch motor
      YS3, 4, 6, 8 = Yaskawa 3, 4, 6 and 8 inch motors

       

      Not available with inline motor mount, contact your local sales representative

      MM = Mechanical Options

      Limit Switches

      FT35, FT60, FT80
      OptionQuantityPart NumberDescription
      L1114453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2214453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L3314453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4N/A
      L5N/A
      L6N/A
      FT45
      OptionQuantityPart NumberDescription
      L1143403Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2243404Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L31
      2
      43403
      43404
      Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4167634Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L5267635Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L61
      2
      67634
      67635
      Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
  • FT45
    • Performance Specifications

      FT45 Mechanical Specifications

        High
      Capacity
       Standard
      Capacity
       
      510510
      Screw Leadin0.1970.3940.1970.394
      mm510510
      Maximum Force*lbf10000100001000010000
      kN44.544.544.544.5
      Estimated L_10 Life at Maximum Forcein x 10^69.8119.145.6711.06
      km249.2486.3144280.9
      C_a (Dynamic Load Rating)lbf36800365003065030400
      kN163.7162.4136.3135.2
      Maximum Input Torquelbf-in392783392783
      Nm44.188.244.188.2
      Max Rated RPM @ Input ShaftRPM3500350035003500
      Maximum Linear Speed @
      Maximum Rated RPM
      in/sec11.52311.523
      mm/sec292583292583
      *Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

       

      FT45 Inertias

       5 mm Lead10 mm Lead 
      NMT Unit - J (0)0.0024630.002474kg-m² (at input shaft) kg-m²/inch of stroke
      NMT Unit - J (Stroke)0.0000450.000046kg-m² (at input shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (0)0.0025710.002581kg-m² (at motor shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (Stroke)0.0000450.000046kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (0)0.0069110.006921kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (Stroke)0.0000450.000046kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (0)0.0034660.003469kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (Stroke)0.0000110.000011kg-m² (at motor shaft) kg-m²/inch of stroke
      Standard Inline Coupling Inertia0.00010743 kg-m²
      (0.000951 lbf-in s²)
      *Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

       

      FT45 Weights

      Base Actuator Weightlbkg
      6 Inch Stroke Length5726
      12 Inch Stroke Length6831
      18 Inch Stroke Length7936
      24 Inch Stroke Length9041
      36 Inch Stroke Length11251
      48 Inch Stroke Length13561
      Adder for Inline (excluding motor)7.13.2
      Adder for Parallel Drive (excluding motor)42.519.3
      Adder for Front Flange6.12.8
      Adder for Rear Flange17.47.9
      Adder for Rear Clevis18.98.6
      Adder for Rear Eye19.89
      Adder for Front/Rear Angle MountsNANA
      Adder for Two Trunnions17.27.8
      Adder for Two Foot Mounts10.44.7
    • Data Curves

      FT45 Critical Speed


       

      FT45 Max Force

    • Estimated Life Time Curves

      FT45 Series Life Curves (3)


      FT45A Series Life Curves

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      FT Order

       

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AA = Frame Size

      35 = 3.5 inch (90 mm)
      45 = 4.8 inch (122 mm)
      60 = 6.4 inch (162 mm)
      80 = 8.5 inch (216 mm)

       

      BB = Stroke Length

      06 = 6 inch (152 mm) FT35
      12 = 12 inch (305 mm) FT35, 45, 60, 80
      18 =18 inch (457 mm) FT35, 45
      24 = 24 inch (610 mm) FT35, 45, 60, 80
      36 = 36 inch (914 mm) FT35, 45, 60, 80
      48 = 48 inch (1219 mm) FT35, 45, 60, 80

       

      CC= Screw Lead

      05 = 0.2 inch, FT35, 45
      06 = 0.23 inch, FT60, 80
      10 = 0.39 inch, FT35, 45
      12 = 0.47 inch, FT60, 80
      20 = 0.79 inch, FT35
      30 = 1.18 inch, FT60, 80

       

      D = Mounting Style

      N = None
      F = Front flange, English
      Z = Front flange, Metric, FT45
      R = Rear flange, English 1,2
      C = Rear clevis, English 1,2
      G = Rear clevis, Metric 1,2
      Y = Rear eye, English 1, FT45
      W = Rear eye, Metric 1, FT45
      L = Side lugs
      S = Side mount, English, FT35, 60, 80
      J = Side mount, Metric, FT35, 60, 80
      T = Side trunnion mount, English 2,3, FT35, 60, 80
      Q = Side trunnion mount, Metric 2,3, FT35, 60, 80
      2 = Rear trunnion mount, English, FT45
      P = Rear trunnion mount, Metric, FT45
      E = Extended tie rods, English
      M = Extended tie rods, Metric

       

      Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

       

      1. Not available with inline motor mount, contact your local sales representative.
      2. Application details must be discussed for an FT80
      3. IP65 environmental sealing option not available

       

       

      E= Motor Mounting Configurations

      N = None
      I = Inline direct drive (includes Exlar standard coupling)
      P = Parallel, 1:1 belt reduction
      Q = Parallel, 2:1 belt reduction

       

      Maximum Standard Motor Size

      FT35: 5.6 inch/165 mm
      FT45: 7.1 inch/215 mm
      FT60: 7.9 inch/215 mm
      FT80: 8.5 inch/300 mm
      For oversized motors, contact your local sales representative.

       

      F= Rod End

      M= Male, US std. thread
      A= Male, metric thread
      F= Female, US std. thread
      B= Female, metric thread

       

      GGG = Motor Mount Provisions

      AA# = Alpha numeric motor call out – Contact your local sales representative. Motor not included.

       

      NMT = No motor mount – keyed shaft on base unit only
      N23 = Nema 23 standard dimension
      N34 = Nema 34 standard dimension
      N42 = Nema 42 standard dimension
      N56 = Nema 56 standard demension
      M60 = Exlar 60 mm SLM. Motor not included.
      M90 = Exlar 90 mm SLM. Motor not included.
      M11 = Exlar 115 mm SLM and ER. Motor not included.
      M14 = Exlar 142 mm SLM. Motor not included.
      M18 = Exlar 180 mm SLM. Motor not included.
      G60 = Exlar 60 mm SLG. Motor not included.
      G90 = Exlar 90 mm SLG. Motor not included.
      G11 = Exlar 115 mm SLG and ER. Motor not included.
      AB3, 4, 6, 8 = Allen Bradley Ultra 3, 4, 6 and8 inch motors
      BD3, 4, 6, 8 = Baldor 3, 4, 6 & 8 inch motors
      CM3, 4, 6, 8 = Parker (Custom Servo Motors) Metric 3, 4, 6 & 8 inch motors
      EE3, 4 = Emerson EMC Imperial 3 & 4 inch
      EM3, 4, 6, 8 = Emerson EMC Metric 3, 4, 6 &8 inch
      FA 4, 6, 8 = Fanuc 4, 6 & 8 inch motors
      IN3, 4, 6, 8 = Bosch-Rexroth (Indramat) 3, 4, 6 and 8 inch motors
      KM2, 4, 6, 8 = Kollmorgen B & M 20, 40, 60 and80 Series
      MT3, 4, 6, 8 = Mitsubishi 3, 4, 6 & 8 inch motors
      PS3, 4, 6, 8 = Pacific Scientific PMA/PMB Series
      PC2, 3, 4, 6 = Parker Compumotor Apex 2.7, 3.6, 4.5 and 5.6 inch
      SM2 = Siemens 2 inch motor
      SM3 = Siemens 3 inch motor
      YS3, 4, 6, 8 = Yaskawa 3, 4, 6 and 8 inch motors

       

      Not available with inline motor mount, contact your local sales representative

      MM = Mechanical Options

      Limit Switches

      FT35, FT60, FT80
      OptionQuantityPart NumberDescription
      L1114453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2214453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L3314453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4N/A
      L5N/A
      L6N/A
      FT45
      OptionQuantityPart NumberDescription
      L1143403Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2243404Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L31
      2
      43403
      43404
      Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4167634Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L5267635Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L61
      2
      67634
      67635
      Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
  • FT60
    • Performance Specifications

      FT60 Mechanical Specifications

        High
      Capacity
        Standard
      Capacity
        
      6123061230
      Screw Leadin0.2360.4721.1810.2360.4721.181
      mm6123061230
      Maximum Force ^1lbf200002000020000200002000020000
      kN898989898989
      Estimated L_10 Life at Maximum Forcein x 10^65.77.338.64.15.210.7
      km145.8184.7981.1104.8133.1271.9
      C_a (Dynamic Load Rating)lbf579334975063958519004460041700
      kN257.7221.3284.5230.9198.4185.5
      Maximum Input Torquelbf-in9401880469994018804699
      Nm106212531106212531
      Max Rated RPM @ Input ShaftRPM200020002000200020002000
      Maximum Linear Speed @
      Maximum Rated RPM
      in/sec7.915.8397.915.839
      mm/sec20140110002014011000
      1 -Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

       

      FT60 Inertias

       6 mm Lead12 mm Lead30 mm Lead 
      NMT Unit - J (0)0.00784640.00787090.0080424kg-m² (at input shaft) kg-m²/inch of stroke
      NMT Unit - J (Stroke)0.00025390.00025470.00026kg-m² (at input shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (0)0.00817640.00820090.0083724kg-m² (at motor shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (Stroke)0.00025390.00025470.00026kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (0)0.01293570.01461130.0312682kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (Stroke)0.00025390.00025470.00026kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (0)0.00491580.00572020.0214777kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (Stroke)0.00006350.00006370.0000650kg-m² (at motor shaft) kg-m²/inch of stroke
      Standard Inline Coupling Inertia0.000330 kg-m²
      (0.002921 lbf-in s²)
      *Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

       

      FT60 Weights

      Base Actuator Weightlbkg
      12 inch Stroke Length10045
      24 inch Stroke Length13059
      36 Inch Stroke Length16072
      48 Inch Stroke Length19086
      Adder for Inline (excluding motor)20.49.3
      Adder for Parallel Drive (excluding motor)39.117.7
      Adder for Front Flange13.46.1
      Adder for Rear Flange15.97.2
      Adder for Rear Clevis11.15
      Adder for Rear EyeNANA
      Adder for Front/Rear Angle MountsNANA
      Adder for Two Trunnions44.320.1
      Adder for Two Foot Mounts10.44.7
    • Data Curves

      FT60 Critical Speed


      FT60 Max Force

    • Estimated Life Time Curves

      FT60 Series Life Curves


      FT60A Series Life Curves

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      FT Order

       

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AA = Frame Size

      35 = 3.5 inch (90 mm)
      45 = 4.8 inch (122 mm)
      60 = 6.4 inch (162 mm)
      80 = 8.5 inch (216 mm)

       

      BB = Stroke Length

      06 = 6 inch (152 mm) FT35
      12 = 12 inch (305 mm) FT35, 45, 60, 80
      18 =18 inch (457 mm) FT35, 45
      24 = 24 inch (610 mm) FT35, 45, 60, 80
      36 = 36 inch (914 mm) FT35, 45, 60, 80
      48 = 48 inch (1219 mm) FT35, 45, 60, 80

       

      CC= Screw Lead

      05 = 0.2 inch, FT35, 45
      06 = 0.23 inch, FT60, 80
      10 = 0.39 inch, FT35, 45
      12 = 0.47 inch, FT60, 80
      20 = 0.79 inch, FT35
      30 = 1.18 inch, FT60, 80

       

      D = Mounting Style

      N = None
      F = Front flange, English
      Z = Front flange, Metric, FT45
      R = Rear flange, English 1,2
      C = Rear clevis, English 1,2
      G = Rear clevis, Metric 1,2
      Y = Rear eye, English 1, FT45
      W = Rear eye, Metric 1, FT45
      L = Side lugs
      S = Side mount, English, FT35, 60, 80
      J = Side mount, Metric, FT35, 60, 80
      T = Side trunnion mount, English 2,3, FT35, 60, 80
      Q = Side trunnion mount, Metric 2,3, FT35, 60, 80
      2 = Rear trunnion mount, English, FT45
      P = Rear trunnion mount, Metric, FT45
      E = Extended tie rods, English
      M = Extended tie rods, Metric

       

      Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

       

      1. Not available with inline motor mount, contact your local sales representative.
      2. Application details must be discussed for an FT80
      3. IP65 environmental sealing option not available

       

       

      E= Motor Mounting Configurations

      N = None
      I = Inline direct drive (includes Exlar standard coupling)
      P = Parallel, 1:1 belt reduction
      Q = Parallel, 2:1 belt reduction

       

      Maximum Standard Motor Size

      FT35: 5.6 inch/165 mm
      FT45: 7.1 inch/215 mm
      FT60: 7.9 inch/215 mm
      FT80: 8.5 inch/300 mm
      For oversized motors, contact your local sales representative.

       

      F= Rod End

      M= Male, US std. thread
      A= Male, metric thread
      F= Female, US std. thread
      B= Female, metric thread

       

      GGG = Motor Mount Provisions

      AA# = Alpha numeric motor call out – Contact your local sales representative. Motor not included.

       

      NMT = No motor mount – keyed shaft on base unit only
      N23 = Nema 23 standard dimension
      N34 = Nema 34 standard dimension
      N42 = Nema 42 standard dimension
      N56 = Nema 56 standard demension
      M60 = Exlar 60 mm SLM. Motor not included.
      M90 = Exlar 90 mm SLM. Motor not included.
      M11 = Exlar 115 mm SLM and ER. Motor not included.
      M14 = Exlar 142 mm SLM. Motor not included.
      M18 = Exlar 180 mm SLM. Motor not included.
      G60 = Exlar 60 mm SLG. Motor not included.
      G90 = Exlar 90 mm SLG. Motor not included.
      G11 = Exlar 115 mm SLG and ER. Motor not included.
      AB3, 4, 6, 8 = Allen Bradley Ultra 3, 4, 6 and8 inch motors
      BD3, 4, 6, 8 = Baldor 3, 4, 6 & 8 inch motors
      CM3, 4, 6, 8 = Parker (Custom Servo Motors) Metric 3, 4, 6 & 8 inch motors
      EE3, 4 = Emerson EMC Imperial 3 & 4 inch
      EM3, 4, 6, 8 = Emerson EMC Metric 3, 4, 6 &8 inch
      FA 4, 6, 8 = Fanuc 4, 6 & 8 inch motors
      IN3, 4, 6, 8 = Bosch-Rexroth (Indramat) 3, 4, 6 and 8 inch motors
      KM2, 4, 6, 8 = Kollmorgen B & M 20, 40, 60 and80 Series
      MT3, 4, 6, 8 = Mitsubishi 3, 4, 6 & 8 inch motors
      PS3, 4, 6, 8 = Pacific Scientific PMA/PMB Series
      PC2, 3, 4, 6 = Parker Compumotor Apex 2.7, 3.6, 4.5 and 5.6 inch
      SM2 = Siemens 2 inch motor
      SM3 = Siemens 3 inch motor
      YS3, 4, 6, 8 = Yaskawa 3, 4, 6 and 8 inch motors

       

      Not available with inline motor mount, contact your local sales representative

      MM = Mechanical Options

      Limit Switches

      FT35, FT60, FT80
      OptionQuantityPart NumberDescription
      L1114453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2214453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L3314453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4N/A
      L5N/A
      L6N/A
      FT45
      OptionQuantityPart NumberDescription
      L1143403Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2243404Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L31
      2
      43403
      43404
      Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4167634Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L5267635Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L61
      2
      67634
      67635
      Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
  • FT80
    • Performance Specifications

      FT80 Mechanical Specifications

        High
      Capacity
        Standard
      Capacity
        
      6123061230
      Screw Leadin0.2360.4721.1810.2360.4721.181
      mm6123061230
      Maximum Force^1lbf400004000040000400004000040000
      kN177.9177.9177.9177.9177.9177.9
      Estimated L_10 Life at Maximum Forcein x 10^63.14.416.31.942.555
      km78.7111.4414.349.364.9127
      C_a (Dynamic Load Rating)lbf943308407995971807007020064700
      kN419.6374426.9359312.2287.8
      Maximum Input Torquelbf-in188037609399188037609399
      Nm21242510622124251062
      Max Rated RPM @ Input ShaftRPM175017501750175017501750
      Maximum Linear Speed @
      Maximum Rated RPM
      in/sec6.913.834.46.913.834.4
      mm/sec175351875175351875
      1- Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

       

      FT80 Inertias

       6 mm Lead12 mm Lead30 mm Lead 
      NMT Unit - J (0)0.03025040.03032750.0308673kg-m² (at input shaft) kg-m²/inch of stroke
      NMT Unit - J (Stroke)0.00080220.00080350.0008124kg-m² (at input shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (0)0.03146040.03153750.0320773kg-m² (at motor shaft) kg-m²/inch of stroke
      Inline w/ Coupler - J (Stroke)0.00080220.00080350.0008124kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (0)0.07210560.05355330.1342578kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 1:1 - J (Stroke)0.00080220.00080350.0008124kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (0)0.01987650.0270490.0753395kg-m² (at motor shaft) kg-m²/inch of stroke
      Parallel 2:1 - J (Stroke)0.00020060.00020090.0002031kg-m² (at motor shaft) kg-m²/inch of stroke
      Standard Inline Coupling Inertia0.0001210 kg-m²
      (0.010709 lbf-in s²)
      *Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

       

      FT80 Weights

      Base Actuator Weightlbkg
      12 Inch Stroke Length19086
      24 Inch Stroke Length265120
      36 Inch Stroke Length340153
      48 Inch Stroke Length415187
      Adder for Inline (excluding motor)54.924.9
      Adder for Parallel Drive (excluding motor)79.135.9
      Adder for Front Flange28.517.5
      Adder for Rear FlangeNANA
      Adder for Rear ClevisNANA
      Adder for Rear EyeNANA
      Adder for Front/Rear Angle MountsNANA
      Adder for Two TrunnionsNANA
      Adder for Two Foot Mounts34.815.8
    • Data Curves

      FT80 Critical speed


       

      FT80 Max Force

    • Estimated Life Time Curves

      FT80 Series Life Curves


      FT80A Series Life Curves

    • Ordering Guide

      To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

       

      FT Order

       

      Product Selection Guidelines

      To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

      AA = Frame Size

      35 = 3.5 inch (90 mm)
      45 = 4.8 inch (122 mm)
      60 = 6.4 inch (162 mm)
      80 = 8.5 inch (216 mm)

       

      BB = Stroke Length

      06 = 6 inch (152 mm) FT35
      12 = 12 inch (305 mm) FT35, 45, 60, 80
      18 =18 inch (457 mm) FT35, 45
      24 = 24 inch (610 mm) FT35, 45, 60, 80
      36 = 36 inch (914 mm) FT35, 45, 60, 80
      48 = 48 inch (1219 mm) FT35, 45, 60, 80

       

      CC= Screw Lead

      05 = 0.2 inch, FT35, 45
      06 = 0.23 inch, FT60, 80
      10 = 0.39 inch, FT35, 45
      12 = 0.47 inch, FT60, 80
      20 = 0.79 inch, FT35
      30 = 1.18 inch, FT60, 80

       

      D = Mounting Style

      N = None
      F = Front flange, English
      Z = Front flange, Metric, FT45
      R = Rear flange, English 1,2
      C = Rear clevis, English 1,2
      G = Rear clevis, Metric 1,2
      Y = Rear eye, English 1, FT45
      W = Rear eye, Metric 1, FT45
      L = Side lugs
      S = Side mount, English, FT35, 60, 80
      J = Side mount, Metric, FT35, 60, 80
      T = Side trunnion mount, English 2,3, FT35, 60, 80
      Q = Side trunnion mount, Metric 2,3, FT35, 60, 80
      2 = Rear trunnion mount, English, FT45
      P = Rear trunnion mount, Metric, FT45
      E = Extended tie rods, English
      M = Extended tie rods, Metric

       

      Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

       

      1. Not available with inline motor mount, contact your local sales representative.
      2. Application details must be discussed for an FT80
      3. IP65 environmental sealing option not available

       

       

      E= Motor Mounting Configurations

      N = None
      I = Inline direct drive (includes Exlar standard coupling)
      P = Parallel, 1:1 belt reduction
      Q = Parallel, 2:1 belt reduction

       

      Maximum Standard Motor Size

      FT35: 5.6 inch/165 mm
      FT45: 7.1 inch/215 mm
      FT60: 7.9 inch/215 mm
      FT80: 8.5 inch/300 mm
      For oversized motors, contact your local sales representative.

       

      F= Rod End

      M= Male, US std. thread
      A= Male, metric thread
      F= Female, US std. thread
      B= Female, metric thread

       

      GGG = Motor Mount Provisions

      AA# = Alpha numeric motor call out – Contact your local sales representative. Motor not included.

       

      NMT = No motor mount – keyed shaft on base unit only
      N23 = Nema 23 standard dimension
      N34 = Nema 34 standard dimension
      N42 = Nema 42 standard dimension
      N56 = Nema 56 standard demension
      M60 = Exlar 60 mm SLM. Motor not included.
      M90 = Exlar 90 mm SLM. Motor not included.
      M11 = Exlar 115 mm SLM and ER. Motor not included.
      M14 = Exlar 142 mm SLM. Motor not included.
      M18 = Exlar 180 mm SLM. Motor not included.
      G60 = Exlar 60 mm SLG. Motor not included.
      G90 = Exlar 90 mm SLG. Motor not included.
      G11 = Exlar 115 mm SLG and ER. Motor not included.
      AB3, 4, 6, 8 = Allen Bradley Ultra 3, 4, 6 and8 inch motors
      BD3, 4, 6, 8 = Baldor 3, 4, 6 & 8 inch motors
      CM3, 4, 6, 8 = Parker (Custom Servo Motors) Metric 3, 4, 6 & 8 inch motors
      EE3, 4 = Emerson EMC Imperial 3 & 4 inch
      EM3, 4, 6, 8 = Emerson EMC Metric 3, 4, 6 &8 inch
      FA 4, 6, 8 = Fanuc 4, 6 & 8 inch motors
      IN3, 4, 6, 8 = Bosch-Rexroth (Indramat) 3, 4, 6 and 8 inch motors
      KM2, 4, 6, 8 = Kollmorgen B & M 20, 40, 60 and80 Series
      MT3, 4, 6, 8 = Mitsubishi 3, 4, 6 & 8 inch motors
      PS3, 4, 6, 8 = Pacific Scientific PMA/PMB Series
      PC2, 3, 4, 6 = Parker Compumotor Apex 2.7, 3.6, 4.5 and 5.6 inch
      SM2 = Siemens 2 inch motor
      SM3 = Siemens 3 inch motor
      YS3, 4, 6, 8 = Yaskawa 3, 4, 6 and 8 inch motors

       

      Not available with inline motor mount, contact your local sales representative

      MM = Mechanical Options

      Limit Switches

      FT35, FT60, FT80
      OptionQuantityPart NumberDescription
      L1114453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2214453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L3314453Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4N/A
      L5N/A
      L6N/A
      FT45
      OptionQuantityPart NumberDescription
      L1143403Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L2243404Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L31
      2
      43403
      43404
      Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L4167634Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L5267635Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      L61
      2
      67634
      67635
      Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
      Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)